Skip to main content

Motor Winding


LAKSHMI 0.5HP


Centrifugal regenerative pump
Monobloc
1 PH, 240V, 50Hz
Duty S1, Class’B’, CSR tech type
HP               0.5
Capacitor   12.5mfd
Head           18m.
Current       3A
Speed         2850rpm
Size            25*25mm












WINDING
Starting winding                                                                               Runningwinding
27 swg, 350gm,                                                                                          24 swg, 450gm,
1-8            50                                                                                    1-6               40
1-10          110                                                                                  1-8                80
1-12          110                                                                                  1-10              80
                                                                                                         1-12              80

Comments

Popular posts from this blog

Fleming's left hand rule

Fleming's left hand rule The direction of force produced on a current-carrying cunductor placed in magnetic field can be determined by this rule. as shown in photo hold the thumb,forefinger and middle finger of the left hand mutually at right angles to each other., such that the forefinger is in the direction of current flow in the cunductor; then the thumb indicates the direction of motion of the conductor.

Fleming's right hand rule

Fleming's right hand rule The direction of dynamically induced emf can be identified by this rule.Hold the thumb,forefinger and middle finger of the right hand at the right angles to each other as shown in the photo such that the forefinger is in the direction of the motion of the conductor, then the middle finger indicates the direction of emf induced. i.e.towards the observer or away from the observer.